CMM Calibration and Repair


Request a scoped quote for your machine's make, model and volume.

Request a quotation

A written quotation follows by email.

Calibration versus verification

Calibration establishes the relationship between a machine's indications and a reference value, with a stated uncertainty. What most buyers order is a performance verification against ISO/IEC 17025:2017-aligned criteria, or against ASME B89.4.1 by customer preference.

Both are handled the same way here: geometric adjustment where indicated, error-map compensation where the controller permits it, and a certificate that states what was actually done.

What a visit covers

The same sequence applies whether the result is destined for an acceptance test or a routine reverification, and no step is shortened for either one.

  • 01

    Scale and reader head

    X, Y and Z scales are cleaned and inspected; reader head output is checked and adjusted.

  • 02

    Air bearings and airlines

    Bearing condition and supply air quality are checked before any geometric test proceeds.

  • 03

    Geometry

    Straightness, linearity and squareness are checked in the XY, ZX and ZY planes.

  • 04

    Length measurement error

    E0 and E1 tested per ISO 10360-2, 105 measurements across five lengths and seven positions.

  • 05

    Probing error

    PFTU tested on a calibrated reference sphere separate from the probe qualification sphere, per ISO 10360-5.

Sequence of work

  • 01

    As-found

    Geometry and length error are recorded before any adjustment is made.

  • 02

    Adjustment

    Kinematic errors and squareness are corrected where the machine allows it.

  • 03

    Compensation

    Volumetric error map is updated on controllers where OEM access permits.

  • 04

    As-left

    Full verification is repeated and results are issued on certificate.

Why Indianapolis CMM Calibration and Repair

  • 01

    As-found is never skipped

    Impact assessment back to the last passing calibration depends on it.

  • 02

    Repair and verification together

    Probe, scale, air bearing and drive repair are followed by re-verification, not assumed.

  • 03

    Environment checked first

    Thermal soak and gradient are confirmed before test lengths are measured.

Coverage across Indiana and the Greater Midwest

Service area covers Indianapolis and the metros listed on this site. Travel terms and scheduling are confirmed at quote.

Discuss CMM Calibration Requirements

Machine make, model and volume are all a quote needs to start.